The DeltaVision uses fixed manual dichroics/polychroics and you need to choose the right one for your fluorophores. This a wheel underneath the objectives, a small number (that isn't particularly easy to see) at the front indicates which dichroic is in place. University of SouthamptonMissing: deltavision. 4 DeltaVision OMX SR Structured Illumination AA Figure 1. Comparison - Standard Widefield (Left) and Structured Illumination (Right) Two isoforms of beta-tubulin in a cultured neuron - Image courtesy of Stephanie Kaech Petrie and Aurelie Snyder, Advanced Light Microscopy Core at The Jungers Institute Oregon Health Sciences University.
Microscope: The DeltaVision II Microscope System uses an Olympus IX inverted microscope with a xenon arc lamp as the illumination source for exciting fluorophores from the UV to far Red. It can also collect transmitted LED light images (bright field and DIC). It has 60x and x (oil) objectives. 20x and 40x (dry) objectives can be switched from the other DV system. Microscope: The Applied Precision DeltaVision Microscope System I uses a standard Olympus IX inverted microscope with a xenon arc lamp as the illumination source for exciting fluorophores from the UV to far Red. It can also collect transmitted light images (bright field and DIC). It has 20x, 40x (dry), 60x and x (oil) objectives. Filter Sets: It contains the filter sets for imaging DAPI. DeltaVision Elite is a fully integrated, flexible, widefield fluorescence microscope optimized for live cell imaging. The DeltaVision Elite's efficient light path and optimized deconvolution algorithm combine to deliver superior image quality while maintaining cell viability. Fully integrated system for seamless operation.
This manual shows how to use the DeltaVision system to acquire images. It also shows how to maintain the system. About This Manual describes the information in each chapter. Document Conventions explains the typography, notes, and other conventions used in this manual. Contacting Applied Precision, LLC provides information about how to contact. Optimized deconvolution. Solid-state illumination, fast excitation switching. Temperature, humidity, CO2 control. Hardware-based autofocus. High-precision XYZ stage. Dual cameras - high-resolution and high-sensitivity. nm and nm lasers for photoactivation and photo-bleaching experiments. Optical axis integration/z-sweep acquisition. 4 DeltaVision OMX SR Structured Illumination AA Figure 1. Comparison - Standard Widefield (Left) and Structured Illumination (Right) Two isoforms of beta-tubulin in a cultured neuron - Image courtesy of Stephanie Kaech Petrie and Aurelie Snyder, Advanced Light Microscopy Core at The Jungers Institute Oregon Health Sciences University.
0コメント